Sensitivity to Water Content:

The use of polycarboxylate superplasticizers significantly reduces the water content required for concrete; typically, the water content per cubic meter ranges from 130 to 165 kg, with water-binder ratios between 0.3 and 0.4 (or even below 0.3). At such low water levels, fluctuations in the added water quantity can cause drastic changes in slump, potentially leading to a sudden increase in the slump of the concrete mixture and resulting in bleeding.

Case Study: A ready-mixed concrete plant produced C30 concrete using P-O 32.5R cement from a specific manufacturer. The contract required a slump of 150 ± 30 mm upon delivery to the site. Although the measured slump was 180 mm at the plant, site testing recorded 210 mm. Two consecutive truckloads were rejected; upon return to the plant, the slump remained 210 mm, accompanied by bleeding and segregation.

Cause: The cement exhibited high compatibility with the superplasticizer, and the dosage used was slightly excessive. Furthermore, the mixing time was insufficient; the slump measured immediately after discharge did not reflect the true slump of the concrete.

Prevention: For cements sensitive to polycarboxylate superplasticizer dosages, the dosage must be carefully controlled with high metering precision. Mixing time should be appropriately extended; even when using twin-shaft forced mixers, the mixing time should not be less than 40 seconds, and ideally should exceed 60 seconds.

SNF-B (5)

Excessive dosage leading to surface air bubbles in concrete structures:

From the perspectives of pumpability and durability, a moderate amount of air entrainment is beneficial; however, many polycarboxylate superplasticizers exhibit relatively high air-entraining properties. Like naphthalene-based superplasticizers, polycarboxylate superplasticizers have a saturation point; this point varies depending on the cement type and dosage. If the admixture dosage is already near its saturation point, the fluidity of the concrete mixture should be improved by adjusting the paste content or employing other methods rather than increasing the admixture dosage.

Phenomenon: A concrete batching plant had been using polycarboxylate superplasticizers for production. One day, a construction site reported that, after formwork removal, the shear wall surfaces exhibited excessive air bubbles and a poor visual finish.

Cause: On the day of casting, the site repeatedly reported low slump and poor fluidity, prompting the batching plant’s laboratory staff to increase the admixture dosage. The site utilized large, standardized steel formwork; however, excessive concrete was poured in a single lift, and vibration was uneven. Prevention: Strengthen communication with the construction site and recommend strictly adhering to specifications regarding pour height and vibration methods. Improve the fluidity of the concrete mixture by adjusting the paste content or using other methods.